Setting Up The Unit
Types of Machine Error
There are many types of machine error, including pitch, roll, yaw, flatness, straightness, and
Abbé error. The diagrams below demonstrate these errors.
Way errors
Pitch
Axis
Yaw
Axis
Typical Yaw
Deviation
Straightness
Roll Axis
Travel
Flatness
Typical Pitch
Deviation
Linear Error Compensation
In this mode, you can apply a single constant correction factor for each axis to all displayed
measurements. You calculate the correction factor, and specify it in parts per million (ppm).
In this mode a single constant correction factor for each axis is applied to all displayed
measurements.
As you follow the procedure you must ensure that you either use a stepped standard, and
approach each edge from the same direction; or if you must approach each edge from
opposite directions, then subtract the width of the tool or measuring probe from the value
displayed on the DP700.
(Fig 1)
Abbé error
A
B
C2
C2
B2
A2
B1
C1
B1
A1
C1
A1
Shown with encoder on concave side
of bearing path
Shown with encoder on convex side of
bearing path
greater than
End Effector
Linear
encoder
Encoder
End Effector
Linear
encoder
Encoderless than
encoder
Error
Travel
Tool or
Probe
Tool o r
Probe
measured distance =
standard distance
standard distance
measured distance